Miniature motor protector, trip current up to 25 A
Temperature- and current-dependent motor protection with multiple terminal arrangements.
Series specifications
- Series reference
- KC-TS-014
- Protection
- Motor & winding protection
- Switch temperature
- 50 to 180 °C
- Temperature tolerance
- ±5 / ±8 °C
- Current / voltage
- 25 A / 15 V DC; 15 A / 30 V DC; 12 A / 125 V AC; 6 A / 250 V AC
- Dimensions / design
- Type A drawing: 18.8 × 8.0 × 2.7 mm including terminal length.
- Tripping
- 1–25 A; 4–10 s at 25 °C ambient
Features and configurations
- Leads and terminals depend on configuration
- Trip current 1–25 A
- Time check at 25 °C ambient
Applications
Window lift, sunroof, wiper and door drives.
Integration and safety
These protective components require professional integration by qualified personnel. Rated current, load type, inrush current, mounting, insulation and restart behaviour must match the application. Switch temperature and allowable ambient temperature are different ratings. Final configuration and applicable documentation are confirmed before ordering.